Primer

A primer ensures the substrate is fully sealed and prepared to receive a coating. It also allows for excellent adhesion between the membrane and the substrate by providing a good key. Chemsol’s Primer solutions offer waterproofing for a variety of requirements.

Chemprime IE
Chemsol Chemprime IE is a ready to use water dilutable primer. It is used for exterior, interior walls before paint application.

Applications

  • Exterior walls and interior walls
  • Brick walls, plastered surface, concrete, etc.

Features

  • Good binding to the substrate.
  • Used for priming interior as well as exterior walls.
  • Excellent adhesion.
  • Provides better resistance to elements.

Method of Application

1. Surface Preparation
  • Surface should be clean and dry and in sound condition.
  • All the surface dirt, grease, loose particles should be removed from the surface. And the surface should be washed thoroughly with clean water.
  • All other previous coatings if any shall be completely removed.
2. New Surfaces
  • The newly constructed surfaces shall be completely cured before coating application.
3. Cracks and Joint Treatment
  • All the surface cracks from 0 - 5mm shall be opened with a 3mm angle grinder.
  • The opened cracks shall be cleaned properly and filled with Chem Crack Fill an acrylic crack-filler.
  • Cracks more than 5mm should be repaired using polymer modified mortar using Chemsol Chemfast SBR. With a cement sand ratio of 1:3 and polymer content of 10% by weight if cement. Allow it to cure as required.
4. Application
  • The surface shall be in clean condition before primer application.
  • Add 40% water to Chemprime IE i.e. 8L water to 20L Chemprime IE. And apply 1 coat of primer on the surface.
  • Let the priming coat dry for 3-4 hrs before subsequent coats are applied.

Precautions and Limitations

  • Do not dilute Chemprime IE with water beyond the recommended proportion.
  • Keep material closed when not in use.
  • Do not apply when rain is expected in short time span.
  • Not to be tinted.

Technical Information

PROPERTIES UNITS RESULTS
Color White
Adhesion to Concrete Excellent
Surface Dry Min 30-45
Finish Smooth

Theoretical Coverage

Material consumption of 8-10M2/L/Coat depending upon the porosity of the substrate.

Pack Size

1L, 4L, 10L & 20L

Storage

Chemsol Chemprime IE shall be placed in a cool and dry place protected from direct sunlight.

Shelf Life

12 months for the date of manufacturing if unopened and stored properly.

Health and Safety

Wash skin with soap and water. On eye contact wash the eyes immediately and consult a physician if irritation persists. On ingestion consult a doctor immediately.
Chemprime IE Eco

Chemsol Chemprime IE Eco is a ready to use water dilutable primer. It is used for exterior, interior walls before paint application.

Applications

  • Exterior walls and interior walls
  • Brick walls, plastered surface, concrete, etc.

Features

  • Good binding to the substrate.
  • Used for priming interior as well as exterior walls.
  • Better adhesion.

Method of Application

1. Surface Preparation

  • Surface should be clean and dry and in sound condition.
  • All the surface dirt, grease, loose particles should be removed from the surface. And the surface should be washed thoroughly with clean water.
  • All other previous coatings if any shall be completely removed.

2. New Surfaces

  • The newly constructed surfaces shall be completely cured before coating application.

3. Cracks and Joint Treatment

  • All the surface cracks from 0 - 5mm shall be opened with a 3mm angle grinder.
  • The opened cracks shall be cleaned properly and filled with Chem Crack Fill an acrylic crack-filler.
  • Cracks more than 5mm should be repaired using polymer modified mortar using Chemsol Chemfast SBR. With a cement sand ratio of 1:3 and

4. Application

  • The surface shall be in clean condition before primer application.
  • Add 50% water to Chemprime IE Eco i.e. 10L water to 20L Chemprime IE Eco. And apply 1 coat of primer on the surface.
  • Let the priming coat dry for 3-4 hrs before subsequent coats are applied.

Precautions and Limitations

  • Do not dilute Chemprime IE Eco with water beyond the recommended proportion.
  • Keep material closed when not in use.
  • Do not apply when rain is expected in short time span.
  • Not to be tinted.

Technical Information

PROPERTIES UNITS RESULTS
Color White
Adhesion to Concrete Excellent
Surface Dry Min 45-55
Finish Smooth

Theoretical Coverage

Material consumption of 8-10M2/L/Coat depending upon the porosity of the substrate.

Pack Size

20L

Storage

Chemsol Chemprime IE Eco shall be placed in a cool and dry place protected from direct sunlight.

Pack Size

1L, 4L, 10L & 20L

Shelf Life

12 months for the date of manufacturing if unopened and stored properly.

Health and Safety

Wash skin with soap and water.
On eye contact wash the eyes immediately and consult a physician if irritation persists.
On ingestion consult a doctor immediately.

Chem Seal Prime

Chemsol Chemseal Prime is a ready to use water dilutable primer. It is used for exterior,
interior walls and terrace before waterproof coating or paint application.

Applications

  • Exterior walls and interior walls
  • Terrace surfaces
  • Brick walls, plastered surface, concrete, etc.

Features

  • Good binding to the substrate.
  • Used for priming interior as well as exterior walls.
  • Penetrates in the substrate and hence has an excellent adhesion.
  • Provides better resistance to efflorescence.

Method of Application

1. Surface Preparation

  • Surface should be clean and dry and in sound condition.
  • All the surface dirt, grease, loose particles should be removed from the surface. And the surface should be washed thoroughly with clean water.
  • All other previous coatings if any shall be completely removed.

2. New Surfaces

  • The newly constructed surfaces shall be completely cured before coating application.

3. Coating

  • All the surface cracks from 0 - 5mm shall be opened with a 3mm angle grinder.
  • The opened cracks shall be cleaned properly and filled with Chem Crack Fill an acrylic crack-filler.
  • Cracks more than 5mm should be repaired using polymer modified mortar using Chemsol Chemfast SBR. With a cement sand ratio of 1:3 and polymer content of 10% by weight if cement. Allow it to cure as required.

4. Application

  • The surface shall be in SSD condition before coating application.
  • Add 100% water to Chemseal Prime i.e. 20L water to 20L Chemseal Prime. And apply 1 coat of primer on the surface.
  • Let the priming coat dry for 3-4 hrs before subsequent coats are applied.

Precautions and Limitations

  • Do not dilute Chemseal Prime with water beyond the recommended proportion.
  • Keep material closed when not in use.
  • Do not apply when rain is expected in short time span.
  • Not to be tinted.

Technical Information

PROPERTIES TEST METHOD UNITS RESULTS
Solid Content
Color White
Adhesion to Concrete Excellent
Surface Dry 30-45 min
Tensile Strength ASTM D 412 N/mm2 2

Theoretical Coverage

Material consumption of 8-10M2/L/Coat depending upon the porosity of the substrate.

Pack Size

20L

Storage

Chemsol Chemseal Prime shall be placed in a cool and dry place protected from direct sunlight.

Shelf Life

24 months for the date of manufacturing if unopened and stored properly.

Health and Safety

Wash skin with soap and water.
On eye contact wash the eyes immediately and consult a physician if irritation persists.
On ingestion consult a doctor immediately.

Chem Metal Prime

Chemsol Chem Metal Prime is a ready to use two component zinc rich primer. It is used to provide excellent corrosion protection to the metal surfaces.

Applications

  • Factories for platforms, pipelines, refineries, petrochemical plants and bridges.
  • Equipment, vessels and machines exposed to atmosphere.
  • Metal roofs, aluminum sheets, etc.

Features

  • Increase life and durability of structure.
  • Excellent corrosion resistant.
  • Fast curing with rapid handling features
  • Easy to apply
  • Excellent bonding to surface.
  • Suitable for both exterior and interior application.
  • Fast drying, high scratch resistance
  • Excellent resistance to water, mild acids, alkali and soluble metal salts.

Method of Application

1. Surface Preparation

  • Surface should be clean and dry and in sound condition.
  • All the surface dirt, grease, heavy rust should be removed from the surface with the help of solvent. Remove weld spatters and sharp edges of welding by grinding.
  • Perform Abrasive blasting with an average surface profile of 40 to 75 microns.
  • Relative humidity of the substrate should not exceed 85% and substrate temperature should be more than 3°C above Dew Point to avoid condensation of moisture onto substrate prior to coating application.
  • All other previous coatings if any shall be completely removed.

2. Application

  • Grind and treat all surface defects after blast cleaning. Remove dust from the surface.
  • Ensure that the surface to be coated is clean, dry and free from any contaminants.

  • Apply Chem Metal Prime immediately after blasting to prevent oxidation and recontamination of the steel surface.
  • Apply Chem Metal Prime with airless spray (preferred method) with tip size of 0.53 – 0.58 mm and at 110 –160 kg/Cm2 pressure.
  • For application with Traditional air spray gun additional dilution may be required. For difficult shapes or touch up application can be done with brush. For brush application Two coats may be required to achieve desired film thickness.
  • In case of oxidation / recontamination, re-blast to the required standard.

Precautions and Limitations

  • Apply mist coat of topcoat paint before final application of top coat to avoid craters or blisters development.
  • Do not over apply. Over application may cause increase in curing time and adhesion failure of overcoating.
  • During or after application, exposure to low temperatures and/or high humidity may cause incomplete cure and thus cause failure in subsequent coat adhesion.
  • Keep material closed when not in use.
  • Do not apply when rain is expected in short time span.

Technical Information

PROPERTIES TEST METHOD UNITS RESULTS
Color Grey
Mix Ratio 4:1
Coating Finish Matt
Surface Dry 30-45 min
Coverage M2/Lit 10-12
DFT Micron 80
Flash Point oC 25

Theoretical Coverage

Material consumption of 10-12M2/L/Coat depending upon the porosity of the substrate.

Pack Size

5L, 20L

Storage

Chemsol Chem Metal Prime shall be placed in a cool and dry place protected from direct sunlight.

Shelf Life

24 months for the date of manufacturing if unopened and stored properly.

Health and Safety

Wash skin with soap and water.
On eye contact wash the eyes immediately and consult a physician if irritation persists.
On ingestion consult a doctor immediately.

Chem Zink Prime

Chemsol Chem Zink Prime is a ready to use two component zinc rich primer. It is used to
provide excellent corrosion protection to the metal surfaces.

Applications

  • Factories for platforms, pipelines, refineries, petrochemical plants and bridges.
  • Equipment, vessels and machines exposed to atmosphere.
  • Metal roofs, aluminum sheets, etc.

Features

  • Increase life and durability of structure.
  • Excellent corrosion resistant.
  • Fast curing with rapid handling features
  • Easy to apply
  • Excellent bonding to surface.
  • Suitable for both exterior and interior application.
  • Fast drying, high scratch resistance
  • Excellent resistance to water, mild acids, alkali and soluble metal salts.

Method of Application

1. Surface Preparation

  • Surface should be clean and dry and in sound condition.
  • All the surface dirt, grease, heavy rust should be removed from the surface with the help of solvent. Remove weld spatters and sharp edges of welding by grinding.
  • Perform Abrasive blasting with an average surface profile of 40 to 75 microns.
  • Relative humidity of the substrate should not exceed 85% and substrate temperature should be more than 3°C above Dew Point to avoid condensation of moisture onto substrate prior to coating application.

  • All other previous coatings if any shall be completely removed.

2. Application

  • Grind and treat all surface defects after blast cleaning. Remove dust from the surface.
  • Ensure that the surface to be coated is clean, dry and free from any contaminants.
  • Apply Chem Zink Prime immediately after blasting to prevent oxidation and recontamination of the steel surface.
  • Apply Chem Zink Prime with airless spray (preferred method) with tip size of 0.53 – 0.58 mm and at 110 –160 kg/Cm2 pressure.
  • For application with Traditional air spray gun additional dilution may be required. For difficult shapes or touch up application can be done with brush. For brush application Two coats may be required to achieve desired film thickness.
  • In case of oxidation / recontamination, re-blast to the required standard.

Precautions and Limitations

  • Apply mist coat of topcoat paint before final application of top coat to avoid craters or blisters development.
  • Do not over apply. Over application may cause increase in curing time and adhesion failure of overcoating.
  • During or after application, exposure to low temperatures and/or high humidity may cause incomplete cure and thus cause failure in subsequent coat adhesion.
  • Keep material closed when not in use.
  • Do not apply when rain is expected in short time span.

Technical Information

PROPERTIES TEST METHOD UNITS RESULTS
Color Grey
Mix Ratio 4:1
Coating Finish Matt
Surface Dry 30-45 min
Coverage M2/Lit 10-12
DFT Micron 80
Flash Point oC 25

Theoretical Coverage

Material consumption of 10-12M2/L/Coat depending upon the porosity of the substrate.

Pack Size

5L, 20L

Storage

Chemsol Chem Zink Prime shall be placed in a cool and dry place protected from direct sunlight.

Shelf Life

24 months for the date of manufacturing if unopened and stored properly.

Health and Safety

Wash skin with soap and water.
On eye contact wash the eyes immediately and consult a physician if irritation persists.
On ingestion consult a doctor immediately.

Chemprime Pro
Chemsol Chemprime Pro is a ready to use water dilutable primer. It is used for exterior, interior walls before paint application.

Applications

  • Exterior walls and interior walls
  • Brick walls, plastered surface, concrete, etc.

Features

  • Excellent binding to the substrate.
  • Used for priming interior as well as exterior walls.
  • Excellent adhesion.
  • Provides excellent resistance to elements.
  • Excellent whiteness on the applied surface.

Method of Application

1. Surface Preparation
  • Surface should be clean and dry and in sound condition.
  • All the surface dirt, grease, loose particles should be removed from the surface. And the surface should be washed thoroughly with clean water.
  • All other previous coatings if any shall be completely removed.
2. New Surfaces
  • The newly constructed surfaces shall be completely cured before coating application.
3. Cracks and Joint Treatment
  • All the surface cracks from 0 - 5mm shall be opened with a 3mm angle grinder.
  • The opened cracks shall be cleaned properly and filled with Chem Crack Fill an acrylic crack-filler.
  • Cracks more than 5mm should be repaired using polymer modified mortar using Chemsol Chemfast SBR. With a cement sand ratio of 1:3 and polymer content of 10% by weight if cement. Allow it to cure as required.
4. Application
  • The surface shall be in clean condition before primer application.
  • Add 100% water to Chemprime Pro i.e. 20L water to 20L Chemprime Pro. And apply 1 coat of primer on the surface.
  • Let the priming coat dry for 3-4 hrs before subsequent coats are applied.

Precautions and Limitations

  • Do not dilute Chemprime Pro with water beyond the recommended proportion.
  • Keep material closed when not in use.
  • Do not apply when rain is expected in short time span.
  • Not to be tinted.

Technical Information

PROPERTIES UNITS RESULTS
Color Bright White
Adhesion to Concrete Excellent
Surface Dry Min 30-45
Finish Smooth

Theoretical Coverage

Material consumption of 8-10M2/L/Coat depending upon the porosity of the substrate.

Pack Size

1L & 20L

Storage

Chemsol Chemprime Pro shall be placed in a cool and dry place protected from direct sunlight.

Shelf Life

12 months for the date of manufacturing if unopened and stored properly.

Health and Safety

Wash skin with soap and water. On eye contact wash the eyes immediately and consult a physician if irritation persists. On ingestion consult a doctor immediately.
Enquire Now